Purpose-built blocks run on a stay-put strategy, which means compartmentation is the fire strategy — a single failed self-closer can compromise a whole corridor. The Fire Safety (England) Regulations 2022 now mandate quarterly communal fire door checks and annual flat entrance door checks in buildings over 11 metres, all recorded for the golden thread. BS 5839-1 and 5839-6 detection, AOV smoke control, door entry, CCTV and ventilation servicing keep managing agents compliant and residents safe.
Fire alarms and evacuation, AOV smoke extract, disabled refuge and PAVA — designed, installed and maintained to current British standards, with monitored response when the alarm actually sounds.
Fire doors, fire stopping, compartmentation, barriers and risk assessments — the protection that works without anyone pressing a button.
Intruder alarms, CCTV, access control, door entry and 24/7 monitoring — the systems that stay awake after the last person leaves.
AHU and ductwork install, service and repair, fire-damper testing, ventilation hygiene, AOV smoke extract, air conditioning and commissioning.
Fire Safety (England) Regulations 2022 door-check duties · Building Safety Act golden thread record-keeping · Stay-put strategy dependent on compartmentation · Managing agent and freeholder liability · Resident expectations on damp, mould and safety.
Every install is delivered to the relevant British / European standard with an audit-ready evidence pack at handover.